Thermostat & Control
PCB Assembly.
Single-sided rigid FR-4 PCB assembly for 24 VAC wall thermostats, hardware temperature switches and remote-probe controllers, with optical AOI, customer firmware loading and agreed bench FCT.
Temperature Sensing & Control.
Boards Built to Your Design.
A thermostat or temperature controller board pairs a defined sensing front end—such as an NTC thermistor, platinum RTD, digital I2C/SMBus sensor or resistor-programmed hardware switch—with threshold, hysteresis or PID logic and a relay, solid-state relay (SSR) or triac output path. We assemble rigid FR-4 thermostat, hardware temperature-switch and remote-probe controller boards with single-sided component mounting, covering automated SMT placement, post-reflow through-hole and mixed assembly, lead-free reflow, first-article review, optical inspection (AOI), approved customer firmware loading, optional drawing-defined conformal coating and agreed electrical bench checks.
Single-sided component mounting does not define copper-layer count, and one SMT reflow face alone does not confirm fit if opposite-face through-hole relays, screw terminals, rotary encoders or battery holders exist; both Top and Bottom Gerbers and the full BOM package list are screened before quoting. Start from a draft BOM, schematic, Gerbers or reference sample while final production files, do-not-populate (DNP) and no-substitution locks, and test limits settle before release. Turnkey IEC 60730-1 / IEC 60730-2-9 Class B or Class C functional-safety firmware development, gas-ignition controls (UL 372 / ANSI Z21.20), Wi-Fi or Matter cloud/app ODM stacks, potting, concealed-joint X-ray inspection, and oil-bath or environmental-chamber temperature calibration stay outside default assembly scope.
From Sensor to Output. Define the Board You Need.
A reliable thermostat or controller build aligns sensing architecture, switching load, mounting geometry and test criteria before files lock. Match your current design stage and board scope to the assembly route that fits.
Board Format & Mounting-Face Check
Board Format & Mounting-Face Check
Wall thermostats often split a front display PCB from a relay backplate, while hardware temperature switches and remote-probe DIN or cabinet controllers pack sensing and switching onto one rigid board. Share both board faces and the complete package list early—copper layer count is separate from single-sided assembly fit, and opposite-face relays, terminals, encoders or battery clips change routing.
Sensor Curve & Output-Path Reference
Sensor Curve & Output-Path Reference
Specify the exact sensing interface rather than a generic temperature range: NTC thermistors require both 25 °C nominal resistance (R25) and the B-value or R-T table, platinum RTDs (PT100, 100 Ω at 0 °C under DIN IEC 60751) require 2-, 3- or 4-wire reference details, and digital I2C/SMBus sensors define register protocols. Pair that with actual load type—NEC Class 2 24 VAC, resistive or inductive (cos φ = 0.4) AC relays, SSRs or triacs.
Hardware Logic & Firmware Boundary
Hardware Logic & Firmware Boundary
Autonomous resistor-coded window switches and comparator bridges run without firmware—on ICs such as TMP390, external E96 resistors select discrete internal lookup bins at power-on reset rather than shifting trip accuracy by resistor tolerance. For MCU-based controllers, we load customer-released production binaries and verify checksums; IEC 60730-1 / IEC 60730-2-9 Class B or Class C functional-safety firmware design stays OEM scope.
Dry Electrical FCT vs. Thermal Calibration
Dry Electrical FCT vs. Thermal Calibration
Factory bench checks verify electrical logic, not metrology certification. We test boards using precision multi-point resistance substitution matched to your NTC/RTD curve, IC-specific electrical trip-test overrides where present (such as TMP390 SETA/SETB), digital bus readback and output switching under agreed pass limits. Real oil-bath or thermal-chamber calibration and enclosure airflow validation remain OEM responsibilities.
Compare Thermostat & Controller Architectures.
Thermostat and temperature-control boards differ by power rail, sensing front end, control logic and switching output. Review four in-scope rigid FR-4 architectures and the component controls and checks each brings into assembly.
24 VAC & Battery-Backed Wall Thermostats
Hardware Resistor-Coded Temperature Switches
Remote-Probe DIN & Panel Controllers
Equipment Cooling & Solid-State Switch Boards
Sense, Switch & Fit. Thermostat Board Engineering Controls.
Thermal isolation, datasheet-matched load switching, clean power paths and mechanical bezel alignment decide whether a thermostat assembly behaves predictably inside a shallow housing. Align these six controls with your released files.
Split Display Front & Relay Backplate
Wall thermostats frequently split user interface electronics (LCD/LED display, tactile buttons and ambient sensor) onto a front PCB while isolating 24 VAC field wiring, screw terminals and switching relays on a wall-mount backplate. Separating the two halves keeps switching heat away from the room sensor and lets each board be screened for single-sided mounting and keyed pin alignment from both Gerbers and enclosure drawings.
Sensor Thermal Isolation & Masking
Solid copper conducts heat orders of magnitude faster than FR-4 or still air, so regulators, displays and relay coils easily bias onboard ambient sensors. Production layouts pull back internal copper planes and mill narrow isolation slots or peninsulas around the sensor. During assembly we verify slot routing, package polarity, no-clean discipline and drawing-defined masking keep-outs around open-cavity humidity/temperature sensors, flagging any hidden-pad package that requires a non-X-ray inspection waiver or leaded alternative.
Relay, Triac/SSR Paths & Isolation Slots
Inductive HVAC coils, valves and fans (cos φ = 0.4) reduce electromechanical relay current and contact life far below resistive (cos φ = 1) ratings—following the actual relay datasheet rather than any blanket derating ratio. We populate approved sealed or flux-protected relays (honoring inter-relay spacing, dual-pin contact routing and no-wash rules), triac RC snubbers or isolated MOSFET SSR transient suppressors and inspect milled isolation slots against customer-owned creepage/clearance drawings; IEC 60730-1 / 60730-2-9 compliance stays OEM.
24 VAC Rectification & Battery Backup
Wall thermostats may run on NEC Class 2 24 VAC with a common (C) wire, battery-only backup or dual-source changeover. Keeping rectifier, reservoir, regulator and battery-backup paths distinct controls standby draw and limits self-heating near the sensor; on shared battery/thermistor circuits we enforce explicit do-not-populate (DNP) selector-resistor BOM locks. Power-stealing stages using chip-scale (WCSP/DSBGA) or hidden-pad (VSON) ICs are flagged during pre-quote BOM screening because concealed-joint X-ray is outside default scope.
Rotary Encoders, UI & Bezel Alignment
Rotary encoders, tactile setpoint keys, 7-segment LEDs and LCD light guides must register squarely with front-bezel openings and actuator travel defined in the mechanical drawing. Post-reflow through-hole insertion and robotic soldering control shaft perpendicularity, seating height and display clearance, while physical option jumpers and panel-bezel gasket boundaries (IEC 60529 enclosure sealing stays with the OEM housing) are verified during first-article review.
Terminal Seating, Wire Entry & FCT Access
Screw terminal blocks and probe sockets on backplates or DIN controllers must seat flush to the PCB so field conductors enter cleanly without straining solder fillets, while maintaining wiring separation between Class 2 sensor leads and switched AC outputs. Because opposite-face through-hole terminals, relays or battery clips break single-sided mounting assumptions even when SMT sits on one face, we inspect both Gerbers pre-quote and confirm pad or terminal access for multi-point resistance substitution and relay-state bench FCT.
Where Your Thermostat Control Boards Are Built.
Once Gerbers, BOM substitution locks, mounting faces and bench-check limits are agreed, production brings rigid FR-4 boards and approved sensing and switching parts together. Your released revision governs every station on the floor.
Automated SMT Placement & Lead-Free Reflow
Temperature sensor ICs, precision E96 or reference resistors, MCU/comparator logic, MOSFET drivers and surface-mount passives populate rigid FR-4 boards from your verified BOM and XY file, then pass through multi-zone lead-free reflow suited to the released packages.
Through-Hole Insertion & Robotic Soldering
Electromechanical relays, screw terminal blocks, probe sockets, rotary encoders, 7-segment displays and battery clips complete mixed thermostat boards after SMT reflow. DIP insertion and desktop robotic soldering maintain flush terminal seating, shaft alignment and repeatable fillets while respecting unsealed relay and sensor masking rules.
First-Article Review & Optical AOI
First-article boards are verified against the released BOM, polarity markings, jumper positions and do-not-populate (DNP) or no-substitution flags before lot continuation. Quality technicians inspect component identity, orientation and accessible solder joints at Maker-ray optical AOI workstations.
Dedicated Functional Test Benches & Firmware
Dedicated functional test benches pair toggle-clamp FCT fixtures and digital bench power supplies for customer-approved firmware loading and agreed dry electrical checks—verifying multi-point resistance-curve trip states, digital sensor bus communication and relay or SSR switching before dispatch.
Temperature-Control Boards Across Three Applications.
Wall thermostats, remote-probe controllers and cabinet cooling modules share a sensing-to-output structure while differing in power rails, thermal layout and mechanical fit. We assemble build-to-print electronics for your released product design.
Wall & Room Thermostats
24 VAC & Battery Control Boards
Wall & Room Thermostats
Non-smart and programmable wall thermostats pair a display front board with a relay or SSR backplate for 24 VAC heating and cooling loads. We assemble single-sided FR-4 boards with thermal isolation slots and customer Class A firmware; cloud/Matter stacks and IEC 60730 agency approvals stay OEM.
DIN & Probe Controllers
NTC, PT100 & Digital Probe Boards
DIN & Probe Controllers
Remote-probe DIN and panel controllers separate the stainless probe from the switching PCB for catering, cold-storage, incubator and process equipment. We lock matched reference BOMs, Class 2/AC terminal separation and multi-point resistance FCT; oil-bath calibration remains OEM.
Equipment Cooling Controllers
Threshold Switches & Fan Outputs
Equipment Cooling Controllers
Enclosure thermal-management boards combine hardware temperature switches or MCU hysteresis logic with relay, triac or SSR fan-switching outputs. We assemble and electrically verify trip logic and output states; variable-speed BLDC motor drives and cabinet airflow validation stay separate.
From Early Control Files to Verified Boards.
Start with the Gerbers, BOM, schematic or reference board available now. Confirming mounting faces, BOM substitution locks and dry electrical FCT criteria before release keeps samples and repeat lots aligned.
Share Files & Control Scope
Send Top and Bottom Gerbers, a draft or released BOM, schematic, assembly drawing or reference sample. Identify the sensor type (NTC R25/B-curve, PT100 RTD, digital IC or hardware switch), output load (24 VAC, relay, SSR or triac), and any firmware or coating keep-outs.
Screen Faces, BOM & Test Plan
We review both board faces and every package footprint to confirm single-sided assembly fit, flag opposite-face THT hardware or bottom-terminated ICs, lock do-not-populate (DNP) and no-substitution rules, and agree dry electrical FCT points and pass limits before release.
Assemble, Solder & Inspect
Bare rigid FR-4 boards and approved parts run through automated SMT placement, lead-free reflow and post-reflow DIP or robotic soldering for relays, terminals and encoders—backed by first-article review, optical AOI and drawing-defined masking.
Flash, Bench-Check & Hand Over
Complete approved customer firmware loading and agreed bench FCT (resistance substitution, bus readback or IC trip-test plus output switching) before dispatch for your enclosure fit, thermal-chamber calibration and repeat-run release.
Common Questions.
Answers to common engineering and sourcing questions on single-sided mounting faces, hardware switch and thermistor BOM control, dry electrical FCT versus thermal calibration, inductive relay ratings and regulatory scope boundaries.
Can multi-layer thermostat boards fit single-sided component mounting?
Yes, provided every SMT and through-hole component mounts on one side of the PCB. Single-sided component mounting does not define copper-layer count—a 2-layer or 4-layer rigid FR-4 board with internal planes pulled back from the sensor zone can still fit, whereas even a 2-layer board with bottom-side SMT parts does not. Because one SMT reflow face alone does not confirm fit if opposite-face through-hole relays, screw terminals, rotary encoders or battery holders exist, both Top and Bottom Gerbers and the full BOM package list are screened before quoting, including flagging hidden-pad packages (such as WSON, VQFN or WCSP/DSBGA) where concealed-joint X-ray is outside default scope.
How do BOM tolerances and sensor curves affect hardware switches versus NTC or RTD boards?
They depend on the actual sensing architecture rather than a single universal rule. On resistor-programmed hardware switches such as the TI TMP390, external E96 resistors on SETA/SETB are read at power-on reset to select discrete internal lookup-table bins—resistor tolerance does not shift trip accuracy, which is set by internal silicon grade—whereas NTC divider and PT100 (100 Ω at 0 °C, DIN IEC 60751) RTD front ends rely directly on matched precision reference resistors, defined 25 °C nominal resistance (R25) and B-value curves, and lead-compensation wiring. We lock exact MPNs, do-not-populate (DNP) option jumpers and no-substitution rules in the Golden BOM before assembly.
What does factory bench FCT verify versus oil-bath or thermal-chamber calibration?
Factory bench FCT performs dry electrical and trip-logic checks using agreed pass limits: multi-point precision resistance substitution taken from your actual NTC R25/B-value or RTD table (never a single undefined resistance point), IC-specific electrical trip-test overrides where supported by the datasheet (such as TMP390 SETA/SETB logic-high test—not a universal pin across all thermostat ICs), digital I2C/SMBus register and alert verification, and relay, SSR or triac output switching. Real stirred-oil-bath metrology, environmental thermal-chamber soak testing and finished-enclosure airflow verification stay outside standard PCBA factory scope and remain OEM responsibilities.
How are inductive relay loads, triac snubbers and sensor masking handled in assembly?
Inductive HVAC loads (such as contactor coils, solenoid valves and fans at cos φ = 0.4) substantially reduce electromechanical relay current and electrical durability compared with resistive ratings (cos φ = 1), so contact selection, inter-relay spacing, parallel high-capacity pin routing and triac RC snubber or SSR transient-suppressor placement must follow the component datasheets and your released layout rather than blanket rules of thumb. On the floor we verify polarity, flush seating, milled isolation slots, unsealed relay no-wash limits and drawing-defined masking keep-outs around open-cavity temperature/humidity sensors.
Are IEC 60730 Class B/C safety firmware, gas-ignition controls or wireless ODM stacks included?
No. We build released rigid FR-4 thermostat and controller designs, load customer-approved operational (Class A) or customer-certified binary firmware, and perform optical AOI, drawing-defined conformal coating and agreed dry electrical bench FCT. Product safety and EMC authorization (including IEC 60730-1 / IEC 60730-2-9 automatic temperature-sensing controls and host FCC/EMC compliance), turnkey Class B or Class C functional-safety firmware R&D, gas-ignition controls (UL 372 / ANSI Z21.20), Wi-Fi or Matter cloud/app ODM stacks, potting, concealed-joint X-ray inspection and thermal-chamber calibration remain outside default scope.
Manufacturing Experience. Direct Cooperation.
Our factory’s experience includes long-term supplier relationships with Fortune Global 500 customers and demanding supplier audits. We bring that manufacturing discipline to sample builds, pilot batches and repeat thermostat and temperature-controller board orders, aligning quality expectations around the released electronics your product requires.
Long-term supplier to Fortune Global 500 customers.
Sustained enterprise supply is part of our manufacturing experience. We apply that experience to build-to-print wall thermostat, hardware switch and remote-probe controller orders, with revision baselines, approved component lists and material responsibilities agreed up front.
Passed demanding supplier audits and customer reviews.
Our factory has passed demanding supplier audits. That background supports direct engineering discussion of mounting-face reviews, sensor and switching BOM controls, masking keep-outs and acceptance limits relevant to your temperature-control assembly.
First-article, الهيئة العربية للتصنيع, and board checks.
First-article review, optical AOI, approved customer firmware loading and agreed dry electrical bench checks examine distinct aspects of the finished controller board. Clear BOM, sensor-curve and load-switching references connect those checks directly to your released revision.
Long-term relationships.
Global brands.
Start with
what you have.
Share your thermostat or temperature-controller board project, intended quantity and the files available now. Top and Bottom Gerbers, a draft BOM, schematic or reference sample is enough to start a practical discussion on mounting faces, sensor/load interfaces and dry electrical FCT scope.
Prototype & sample builds
Start from draft files or a sample board to confirm mounting faces, BOM locks and bench FCT points.
Small-batch & repeat runs
Lock one approved revision, customer firmware binary and dry electrical check plan for repeat lots.